The error codes are somewhat cryptic, but with the assistance of a BE RF Technical Services Engineer, we can assist you in finding the root cause. The codes are:
Admx.x - Loads, Synchronizes and set priorities for the various executables.
Troubleshooting - This alarm normally comes up with another alarm. Look for another alarm and address it.
logx.x - Logging package.
Troubleshooting - Clean edge connectors on installed cards, reseat, and reload software. If problem persist, unit needs to be returned to BE for repair.
cmtx.x - Configuration management (Settings, configurations, etc.).
Troubleshooting - Clean edge connectors on installed cards, reseat, and reload software. If problem persist, unit needs to be returned to BE for repair.
ppsx.x - pulse per second driver.
Troubleshooting - Clean edge connectors on installed cards, reseat, and reload software. If problem persist, unit needs to be returned to BE for repair.
eeix.x - Exgine interface.
Troubleshooting - Reload software and or replace audio board and reload software
l1ctx.x - Layer 1 Control.
Troubleshooting - Clean edge connectors on installed cards, reseat, and reload software. If problem persist, unit needs to be returned to BE for repair.
l2smxtx.x - Layer 2 (data mux).
Troubleshooting - Clean edge connectors on installed cards, reseat, and reload software. If problem persist, unit needs to be returned to BE for repair.
l4mpatx.x - Layer 4 ( HDC encoding).
Troubleshooting - Reload software and or replace motherboard and reload software.
l5mpatx.x - Audio processing & audio card drivers.
Troubleshooting - Intermittent audio board causing software to crash. Reload software and or replace audio board and reload software.
suitx.x - Station user interface.
Troubleshooting - Replace SIC card and reload software.
tsmx.x - Time space module (i.e. GPS).
Troubleshooting - Light Red, cable not hooked up or bad on back of unit. (GPS data in - GPS data out). Light Green, GPS not locked
lmtx.x - Layer Manager.
Troubleshooting - Clean edge connectors on installed cards, reseat, and reload software. If problem persist, unit needs to be returned to BE for repair.
guitx.x - GUI.
Troubleshooting - Reload software.
sistx.x - SIS.
Troubleshooting - Clean edge connectors on installed cards, reseat, and reload software. If problem persist, unit needs to be returned to BE for repair.
eltx.x - Exciter Link.
Troubleshooting - Clean edge connectors on installed cards, reseat, and reload software. If problem persist, unit needs to be returned to BE for repair.
eltmgx.x - Exciter Link manager.
Troubleshooting - Clean edge connectors on installed cards, reseat, and reload software. If problem persist, unit needs to be returned to BE for repair.
verx.x - Version control.
Troubleshooting - Clean edge connectors on installed cards, reseat, and reload software. If problem persist, unit needs to be returned to BE for repair.
bwamtx.x - Bandwidth manager for dynamic configuration changes.
Troubleshooting - Clean edge connectors on installed cards, reseat, and reload software. If problem persist, unit needs to be returned to BE for repair.
hdptx.x - HDP.
Troubleshooting - Clean edge connectors on installed cards, reseat, and reload software. If problem persist, unit needs to be returned to BE for repair.
cmdx.x - Communications Services.
Troubleshooting - Clean edge connectors on installed cards, reseat, and reload software. If problem persist, unit needs to be returned to BE for repair.
My HD generator has went non-operational. What do the error codes mean? Print
Modified on: Tue, 8 Oct, 2019 at 11:05 AM
Did you find it helpful? Yes No